常压下隔热材料冷面温度速查表 | |||||||||||||
热工计算条件:平台立面 环境温度20℃ 1个大气压 风速0 冷面辐射系数0.9 | |||||||||||||
隔热材料热面温度 ℃(密度240~400Kg/m³) | |||||||||||||
隔 热 材 料 厚 度 mm |
| 200 | 300 | 400 | 500 | 600 | 700 | 800 | 850 | 900 | 950 | 1000 | 1000℃ 散热W/m² |
3 | 89 | 122 | 153 | 182 | 213 | 242 | 271 | 285 | 299 | 313 | 328 | 8328 | |
5 | 72 | 97 | 121 | 144 | 168 | 191 | 214 | 226 | 238 | 250 | 262 | 5333 | |
7 | 62 | 82 | 102 | 122 | 141 | 161 | 182 | 192 | 202 | 212 | 223 | 3945 | |
10 | 49 | 64 | 78 | 93 | 109 | 125 | 142 | 150 | 159 | 168 | 177 | 2638 | |
15 | 42 | 52 | 64 | 75 | 87 | 100 | 113 | 120 | 127 | 135 | 142 | 1805 | |
20 |
|
| 55 | 64 | 74 | 85 | 96 | 102 | 108 | 114 | 121 | 1374 | |
25 |
|
|
| 57 | 66 | 75 | 85 | 90 | 95 | 100 | 106 | 1110 | |
30 |
|
|
|
| 60 | 68 | 76 | 81 | 86 | 90 | 95 | 932 | |
35 |
|
|
|
|
| 62 | 70 | 74 | 78 | 83 | 87 | 803 | |
40 |
|
|
|
|
|
| 65 | 69 | 73 | 77 | 81 | 705 | |
45 |
|
|
|
|
|
|
| 65 | 68 | 72 | 76 | 629 | |
50 |
|
|
|
|
|
|
|
| 64 | 69 | 71 | 568 |